| | |
|
| |
| | |
|
|
BW408 All-In-One Steam Boiler Treatment
|
Price: Starting at $115.50
Manufacturer: Cannon Water Technology Inc.
Select Product Options And Calculate Price
| |
|
|
BW-408 All-In-One Steam Boiler Treatment
Nitrite Based Corrosion Protection – Deposit Control – Steam Line Protection
- Designed for steam boilers where more than 80% of the steam condenses into water and returns to the boiler as condensate. Easy to apply. Easy to test.
- Balanced blend of nitrite, borax, azole and polymeric organic dispersants. Protects iron, copper and brass metals.
- Has a dedicated iron oxide dispersants to retard rust deposits.
- Contains a steam line treatment that neutralizes low acidic pH in the condensate return lines.
- Can be used on steam boilers that have hard water makeup, however, for best results soften makeup water.
- BW-408 is intended for use in boilers operating in the low and medium pressure range below 300 psi.
- BW-408 has been successfully used in schools, high rise buildings and apartment buildings where steam is used for heating and there is less than 20% loss of condensate.
-
|
BW-408 Application Rate and Control Parameters
|
- BW408 can be fed by hand or with a chemical metering pump connected to the feed water storage tank or feed water line. If possible, interlock the chemical metering pump to the boiler feed water pump so that chemical is fed in proportion to load. Feed ½-gallon per 100 gallons of boiler water.
- Use Nitrite Test Kit P.N.# CNTK3300-Z to test for BW-408. The recommended test range is 800 - 1500 ppm as Sodium Nitrite. BW-408PD has a pH sensitive color that colors the boiler water a visible red/pink color when the chemical is present. BW-408 does not contain a color indicator dye.
- Log test results. Read Cannon Water Technology Inc.’s “Basic Steam Boiler Water Treatment”.
|
Physical Properties: BW-408
|
|
Form:
|
Liquid
|
Color:
|
Amber /PD= Red
|
|
Odor:
|
Slight Aromatic
|
pH:
|
12+/-
|
|
Density:
|
11.09#/gallon
|
Specific Gravity:
|
1.32
|
|
Freeze Point:
|
Approximately 32° F
|
Freeze/Thaw Recovery:
|
Complete
|
|
Ship Class:
|
Corrosive Liquid, N.O.S. UN 1760
|
|
|
|
Contains:
|
Sodium Hydroxide/Sodium Nitrite PG II
|
|
|
|
HMIS Code:
|
301J
|
|
|
Refer to the MSDS for further health, safety and environmental information regarding this product. Information and recommendations in this bulletin are based on information believed to be reliable. However, the use of the product is beyond the control of Cannon Water Technology Inc. and no guarantee, expressed or implied, is made as to the effects of such the results to be obtained if not used in accordance with directions or established safe practice. The buyer must assume all responsibility, including injury or damage, resulting from misuse of the product as such, or in combination with other material
|
|
Product Reviews
|

See real time shipping rates in shopping cart. No login required.
|
|