MyronL RO-1 Reverse Osmosis DS Meter
|
|
MSRP: $224.00
Price: $199.50
You Save: $24.50 (11 %)
Quantity in stock: unlimited
Item Number: RO-1
Manufacturer: Myron L
Manufacturer Part No: RO-1
|
x
Myron L RO-1 Reverse Osmosis Tester
The
choice of professionals for years, this compact instrument has been
designed specifically to demonstrate and test Point of Use (POU) reverse
osmosis or distillation systems. By measuring electrical conductivity,
it will quickly determine the parts per million/Total Dissolved Solids
(ppm/TDS) of any drinking water.
With
a single “before and after” test, this handy device effectively
demonstrates how your RO or distillation system eliminates harmful
dissolved solids. It will also service test systems, including membrane
evaluation programs.
Features
-
Instant and accurate TDS tests
-
Electronic Internal Standard for easy field calibration
-
Fast Auto Temperature Compensation
-
Rugged design for years of trouble-free testing
-
Simple to use
AUTOMATIC TEMPERATURE COMPENSATION:
Why It Is Important
The
graph below illustrates a TDS reading of a 500 ppm water sample tested
with a non-temperature compensated conductivity meter. The same water
sample appears to have a higher level of TDS when heated (and lower TDS
when chilled). Actually, only conductivity readings change with
temperature. TDS does not change.

Many
instruments ignore the importance of temperature. Others require a
separate thermometer for testing sample temperature, then manual
adjustment of the meter. All Myron L instruments, however, feature fast
and precise Automatic Temperature Compensation. The result: a more
accurate, useful instrument.
HOW CONDUCTIVITY MEASURES ppm/TDS
Total
Dissolved Solids (TDS) conduct electricity. This conductivity allows
measurement of the concentration of these salts directly in parts per
million (ppm). However, the salts’ composition in waters can vary
significantly by location. Since various salts pass current differently,
it was necessary to determine an “average” ppm/ conductivity
relationship. The Myron L Company established the “442” Standard over 40
years ago. It remains the world’s most widely accepted standard of its
kind.
Limited Warranty:
Myron
L RO instruments have a Two (2) Year Limited Warranty. If an instrument
fails to function normally, return it to the factory prepaid. If, in
the opinion of the factory, failure was due to materials or workmanship,
repair or replacement will be made without charge. A reasonable service
charge will be made for diagnosis or repairs due to normal wear, abuse,
or tampering. Warranty is limited to the repair or replacement of the
Myron L instrument only. The Myron L Company assumes no other
responsibility or liability.
|